Securing experimental water and ultrapure water
Purpose of water treatment Securing experimental water (sterile pure water) and reducing costs. Development history A two-stage RO membrane is used to purify sterile pure water from tap water at low cost. Specification Product name (model number) Aseptic pure water equipment How to use Experimental ultrapure water Raw water Tap water Method Activated carbon filtration + RO membrane + UF membrane Scale Production volume 12 m3 / day Delivery location (region) Hyougo in Japan
Improving the quality of experimental water
Purpose of water treatment Secure water to breed microorganisms. Development history Fully automatic operation for 24 hours. Effective use of rainwater and spring water. Specification Product name (model number) UF membrane filtration device How to use Experimental water Raw water Well water Method UF membrane Scale Production volume 530 m3/ day Delivery location (region) National Institute